Golv-/ väggutförande

E 4 version

in conjunction with the expansion joint covers:
• FP(G) 80 NI
• FP(G) 90 NI
• FP(G) 110 NI
• FP 130 NI
• FP 155 NI

E 3 and E 4 versions

in conjunction with the expansion joint covers:
• FP(G) 80/90 B NI
• FP(G) 90/90 B NI
• FP(G) 110/90 B NI
• FP 130/90 B NI
• FP 155/90 B NI

E 2 version

for supports/wall connections in conjunction with the expansion joint covers:
• FP(G) 80 NI
• FP(G) 90 NI
• FP(G) 110 NI
• FP 130 NI
• FP 155 NI

E 5 version

for support connections in conjunction with the expansion
joint covers:
• FP(G) 80 NI
• FP(G) 90 NI
• FP(G) 110 NI
• FP 130 NI
• FP 155 NI

Column skirt wall connection version E 2 or E 3

Please pay special attention when using versions E 2 and E 3:

If the joint is located immediately next to a column or wall, at the beginning and end, two flat brackets are required as intersections (see drawing). This ensures that the expansion joint cover in the floor-floor section is located centrally over the joint. The intersections may be left out if the joint is located in the column-wall vicinity approximately 40 mm from the column/wall. In this case, a floor-wall connection of the AAS sheet is only required at each corner.